Untitled
Abstract: No abstract text available
Text: PR3 Relay Base for: – Octal Relays With DPDT or 3PDT Contacts Universal Modular System The 38 mm 1.496 in. wide PR3 relay base range is a modular system consisting of PR3-B. relay bases, robust REL-OR. electromechanical octal relays with DPDT and 3PDT contacts, and a range of practical
|
Original
|
PDF
|
PR3-BSC1/2x21
PR3-BSC1/3x21
|
Untitled
Abstract: No abstract text available
Text: Module no:0891015 LabelId:0891015 Operator:Phoenix 15:17:29, Donnerstag, 28. Juni 2001 VKK 4-FS Terminal width 7.62 IEC rigid 2 [mm ] solid Connection data flexible stranded AWG 0.2-4 I U [A] [V] 800 ) 0.2-4 24-12 30 STG-MTN 0,5-1,0 0.5-1 20-18 10 ) STG-MTN 1,5-2,5
|
Original
|
PDF
|
0110/Gr.
|
phoenix contacts 30 03 34 7
Abstract: insulation monitoring relay dc isolation VDE 0113 PSR-SCP-24 psr-scp-24uc
Text: PSR – Phoenix Safety Relay PSR-SCP-24 UC/ES.4/3X1/1X2/B – Emergency stop/safety door monitoring – Safety Category 4, EN 954-1 – Plug-in connection terminals – One or two-channel circuit – Cross-circuit detection – Basic insulation – Housing width 22.5 mm 0.886 in.
|
Original
|
PDF
|
PSR-SCP-24
PSR-SCP-24UC/ES.
60204-1/VDE
PSRSCP-24UC/ESM4/2X1/1X2.
PSR-SCP-24UC/
PSR-SCP-24UC/ESM4/3X1/1X2/B
PSR-SCP-24UC/ESA4/3X1/1X2/B
phoenix contacts 30 03 34 7
insulation monitoring relay dc isolation
VDE 0113
psr-scp-24uc
|
PSR-SCP-24
Abstract: PSR-SCP S3435
Text: PSR – Phoenix Safety Relay PSR-SCP-24 UC/ESAM4/8X1/1X2 – Emergency stop/safety door monitoring – Safety Category 4, EN 954-1 – Plug-in connection terminals – One or two-channel circuit – Cross-circuit detection – Safe isolation/basic insulation
|
Original
|
PDF
|
PSR-SCP-24
PSR-SCP-24UC/ESAM4/8x1/1x2
60204-1/VDE
S33/S35:
PSR-SCP-24UC/
PSR-SCP
S3435
|
PSR-SCP-24
Abstract: phoenix contact 24v 8 channel Relay VDE 0113
Text: PSR – Phoenix Safety Relay PSR-SCP-24 UC/ESD/4X1/1X2/600 – Emergency stop/safety door monitoring – Safety Category 4, EN 954-1 – Plug-in connection terminals – Adjustable time 0.05 - 600 sec. – One or two-channel circuit – Cross-circuit detection
|
Original
|
PDF
|
PSR-SCP-24
UC/ESD/4X1/1X2/600
PSR-SCP-24UC/ESD/4X1/1X2/600
60204-1/VDE
phoenix contact 24v 8 channel Relay
VDE 0113
|
Untitled
Abstract: No abstract text available
Text: Module no:1809271 LabelId:1809271 Operator:Phoenix 16:35:17, Donnerstag, 28. Juni 2001 MSTBC 2,5/…-STZFD-5,08 with threaded flange for screw connection to inverted plugs and flange for direct mounting Pitch 5.08 IEC flexible [mm ] stranded 2 I U AWG [A]
|
Original
|
PDF
|
|
PSR-SCP-24
Abstract: No abstract text available
Text: PSR – Phoenix Safety Relay PSR-SCP-24 UC/ES.4/2X1/1X2 – Emergency stop/safety door monitoring – Safety Category 4, EN 954-1 – Plug-in connection terminals – One or two-channel circuit – Safe isolation – Cross-circuit detection – Housing width 22.5 mm 0.886 in.
|
Original
|
PDF
|
PSR-SCP-24
PSR-SCP-24UC/ES.
60204-1/VDE
PSRSCP-24UC/ESM4/2X1/1X2.
mCP24UC/
PSR-SCP-24UC/
PSR-SCP-24UC/ESM4/2X1/1X2
PSR-SCP-24UC/ESA4/2X1/1X2
|
phoenix contacts 30 03 34 7
Abstract: MCC 25 12
Text: Module no:1852176 LabelId:1852176 Operator:Phoenix 16:43:12, Donnerstag, 28. Juni 2001 MCC 1/…-STZ-3,81 with crimp connection and locking chambers for cable grips Pitch 3.81 IEC flexible I U AWG [A] [V] 0.2-0.34 24-22 5 160 0.5-1 20-18 8 160 2 [mm ] stranded
|
Original
|
PDF
|
1/10-STZ-3
1/11-STZ-
81/MCC-MT
81/MCC-MT0
phoenix contacts 30 03 34 7
MCC 25 12
|
Untitled
Abstract: No abstract text available
Text: VARIOSUB D-SUB 15 Contact Inserts, Sleeve Housings VARIOSUB is a range of plug connectors specially designed for signal and data technology in an industrial environment with high degrees of protection, temperatures and mechanical stress. The range is characterized by the simple Push-Pull locking
|
Original
|
PDF
|
VS-ADP16-VS15
VS-ADP24-VS15/RJ45
VS-LWZH/24
45/IP67
|
ME 17,5 tbus 1,5
Abstract: No abstract text available
Text: Modular Electronic Housing ME./TBUS 1. Description The ME.TBUS modular electronic housings have been designed especially for bus applications in which it is frequently necessary to disconnect entire individual modules from the whole. Mounting rail bus connectors ME 17,5 or ME 22,5
|
Original
|
PDF
|
|
X 222 611 01
Abstract: UL 486 torque values Zbf 34 IEC-60664
Text: Thermal-Magnetic Circuit Breaker 4220-T. Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 5 kA , EN/IEC 60934 (6kA) and UL 1077 (5 kA). With toggle actuation, positively trip-free mechanism, a
|
Original
|
PDF
|
4220-T.
X 222 611 01
UL 486 torque values
Zbf 34
IEC-60664
|
Untitled
Abstract: No abstract text available
Text: Thermal-Magnetic Circuit Breaker 4220-T. Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 5 kA , EN/IEC 60934 (6kA) and UL 1077 (5 kA). With toggle actuation, positively trip-free mechanism, a
|
Original
|
PDF
|
4220-T.
|
Untitled
Abstract: No abstract text available
Text: Thermal-Magnetic Circuit Breaker 4220-T. Description Single, double and three pole thermal-magnetic circuit breakers with high rupture capacity to UL 489 5 kA , EN/IEC 60934 (6kA) and UL 1077 (5 kA). With toggle actuation, positively trip-free mechanism, a
|
Original
|
PDF
|
4220-T.
|
AD-TX-EM01
Abstract: ESX10-TD 4616L-160PK esx10-td-101 X22200503 X22261102 ESX10-TA-100-DC24V-0 Sumitomo E4008 phoenix contacts 30 03 34 7 UL2367
Text: Electronic Circuit Protector ESX10-T.-DC 24 V Description Electronic circuit protector type ESX10-T is designed to ensure selective disconnection of DC 24 V load systems. DC 24 V power supplies, which are widely used in industry today, will shut down the output in the event of an overload with the result that
|
Original
|
PDF
|
ESX10-T
ESX10-T
ESX10-T.
AD-TX-EM01
AD-TXEM01
AD-TX-EM01
ESX10-TD
4616L-160PK
esx10-td-101
X22200503
X22261102
ESX10-TA-100-DC24V-0
Sumitomo E4008
phoenix contacts 30 03 34 7
UL2367
|
|
diode in58
Abstract: OMRON POWER RELAY MP2 DMT 98 ATEX G 001 honeywell dcs manual Yokogawa Transducer ABB inverter motor fault code pdt 908
Text: Interface Technology and Switching Devices 2013 / 2014 7 PCB connection technology and electronics housing • PCB terminal blocks and plug-in connectors • Electronics housing Connection technology for field devices • Plug-in connectors • Cables and connectors
|
Original
|
PDF
|
unitB-FLK50/0
VIP-CAB-FLK50/0
VIP-CAB-FLK50/FR/OE/0
diode in58
OMRON POWER RELAY MP2
DMT 98 ATEX G 001
honeywell dcs manual
Yokogawa Transducer
ABB inverter motor fault code
pdt 908
|
12NCFMA2-62
Abstract: ARINC 600 Connector
Text: ca_H1-H116:Layout 1 2/10/11 8:22 AM Page 1 ca_H1-H116:Layout 1 2/10/11 8:22 AM Page 23 ARINC 600 SGA Table of Contents Receptacle SGA Conductive Dust Caps Part Numbers black Plug 025-1183-002 Receptacle 025-1185-002 H Plug SGA SGA connectors utilize all the Signal cavity inserts and contacts from the ARINC 600 connector series. It was designed to be used where there are space
|
Original
|
PDF
|
|
18-P10-Si-20025
Abstract: 18-P10-Si Type NB Breaker 46247 50035-G32 din 46247
Text: Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2.110 V Description Single and two pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics S-type MO or HM
|
Original
|
PDF
|
8340-G2.
18-P10-Si-20025
18-P10-Si
Type NB Breaker
46247
50035-G32
din 46247
|
arinc 600 rack
Abstract: ARINC 600 Connector 12NCFMA2-62 22NCFMA2-40 COUNTERSUNK SOCKET SCREW arinc 620 ESNA nut arinc 600 polarization parts ARINC size 2 dimensions
Text: ARINC 600 Rack and Panel Connectors SGA Available Rear Release/Rear Removable Front Release/Front Removable Low Insertion force contacts. Both environmental and non-environmentl versions. Polarizing post that are removable from the mating face. Field replaceble inserts.
|
Original
|
PDF
|
|
22NCFMA2-40
Abstract: No abstract text available
Text: ARINC 600 Rack and Panel Connectors SGA Available Rear Release/Rear Removable Front Release/Front Removable Low Insertion force contacts. Both environmental and non-environmentl versions. Polarizing post that are removable from the mating face. Field replaceble inserts.
|
Original
|
PDF
|
|
ENV50204
Abstract: IB IL 24 L2
Text: IL DN BK1 DeviceNet Fieldbus Coupler 6 2 7 4 A 0 0 1 Data Sheet 6274C 03/2001 Function The DeviceNet™ Fieldbus Coupler allows the Phoenix Contact Inline I/O modules to communicate on a DeviceNet™ network as a Group 2 slave. The IL DN BK1 is housed in a 4-module
|
Original
|
PDF
|
6274C
ENV50204
IB IL 24 L2
|
Coninvers
Abstract: coninvers D-71083 RC-Z2378 RC-06S1N120000 07P1 RC-5AS2000 RC-12S1N120000 RC-00000001300 RC-Z2092 RC-0000000A000 Coninvers
Text: Circular Connectors In Stock Versions Signal and Universal Coninvers – Connectors for Industrial Automation oninvers is an autonomous company and is the specialist for circular connectors within the Phoenix Contact Group. We develop, design and manufacture our
|
Original
|
PDF
|
D-71083
AE-0004-03
Coninvers
coninvers D-71083
RC-Z2378
RC-06S1N120000
07P1
RC-5AS2000
RC-12S1N120000
RC-00000001300
RC-Z2092
RC-0000000A000 Coninvers
|
Schrack* zf
Abstract: schrack rA schrack ry Schrack zf siemens catalog ST zf schrack
Text: IB ST ZF 24 DIO 8/8R/3 Input/Output Module With Eight Digital Input Channels and Eight Relay Outputs Data Sheet 5154B 5 1 5 4 B 0 0 0 03/2000 Module Description 6 8 6 5 F E U S 4 9 IN T E R B IB S T M E 2 4 D IO U S 8 /8 R /3 , O rd . N o .: 2 7 5 1 8 3 6
|
Original
|
PDF
|
5154B
Schrack* zf
schrack rA
schrack ry
Schrack zf
siemens catalog ST
zf schrack
|
8340-g211-X1F4
Abstract: din 46247
Text: Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2. Description Single, two and three pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics Stype MO or HM CBE to EN 60934 ensures suitability for a wide range
|
Original
|
PDF
|
8340-G2.
8340-g211-X1F4
din 46247
|
Untitled
Abstract: No abstract text available
Text: APPENDIX “A” Contents: Gender Specification Coax Contacts Dielectric Withstanding Voltage Chart Crimp Tool Information Chart Cable Selection Guide VSWR & Transmitted Power Relationships GENDER SPECIFICATION COAX CONTACTS =□ SERIES PDM 950 MHz SLIDE-ON
|
OCR Scan
|
PDF
|
|