Abstract: No abstract text available
Text: INSTALLATION INSTRUCTIONS MALLORY EDELBROCK FUEL INJECTION DISTRIBUTOR EDELBROCK SYSTEM IGNITION AMPLIFIER MALLORY EDELBROCK FUEL INJECTION DISTRIBUTOR 1 NOTE THE POSITION OF #1 CYLINDER ON THE DISTRIBUTOR HOUSING. CONNECT THE #1 SPARK PLUG WIRE AT THIS
|
Original
|
PDF
|
|
delco gm
Abstract: IGNITION CONTROL MODULE
Text: FORM 1486M 03/05 INSTALLATION INSTRUCTIONS HYFIRE® 6.6 SERIES OF ELECTRONIC IGNITION CONTROL HYFIRE® 6.6 IGNITION SYSTEM PART NO. 686M FOR APPLICATIONS TRIGGERED BY POINTS, MALLORY ELECTRONIC IGNITION DISTRIBUTOR ALL MODELS , ORIGINAL EQUIPMENT ELECTRONIC IGNITION AMPLIFIERS AND MAGNETIC TRIGGER
|
Original
|
PDF
|
1486M
1486M
delco gm
IGNITION CONTROL MODULE
|
Mallory Ignition
Abstract: No abstract text available
Text: TROUBLE SHOOTING GUIDE MAGNETIC TRIGGERED DISTRIBUTORS This Trouble Shooting Guide is designed for use with magnetic trigger equipped distributors that are also equipped with a module, such as Mallory 42, 50, 57, 75, 80 and 87 Series distributors along with ACCEL 52,
|
Original
|
PDF
|
1649M
Mallory Ignition
|
Mallory Ignition
Abstract: No abstract text available
Text: FORM 1520 REV. B 09/03 INSTALLATION INSTRUCTIONS 4-STAGE RETARD CONTROL PART NO. 678 Your Mallory HYFIRE 678 Control has a number of built-in features that make it easier to use. These instructions tell how to use these built-in features. First, look at the top of the main unit. You’ll see that there is an
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: HYFIRE VII Series Electronic Ignition Controls Instruction Manual Part#: 667S FORM 1468 REV. B 9/00 INSTALLATION INSTRUCTIONS ® HYFIRE® VIIS SPORTSMAN CD IGNITION SYSTEM Part No. 667S 412 Cylinder Notice: This product is legal for sale or use only on vehicles which may never be used on highways.
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: FORM 1468 REV. B 9/00 INSTALLATION INSTRUCTIONS HYFIRE® VIIS SPORTSMAN CD IGNITION SYSTEM Part No. 667S 412 Cylinder Notice: This product is legal for sale or use only on vehicles which may never be used on highways. The HYFIRE® VIIS Sportsman CD Ignition Controls are not compatible with distributorless systems or
|
Original
|
PDF
|
PN674
|
Untitled
Abstract: No abstract text available
Text: FORM 1670M 08/06 INSTALLATION INSTRUCTIONS NITROUS 6 ELECTRONIC IGNITION CONTROL PART NO 6865M GENERAL INFORMATION The NITROUS 6 includes a single stage RPM limiter and a single stage ignition retard. You can set various settings using the switches that are located in the end
|
Original
|
PDF
|
1670M
6865M
1670M
|
PLACA DE ORIFICIO
Abstract: No abstract text available
Text: Ignition Module Instruction Manual Part#: 605, 609 IGNITION MODULE PN 605 and PN 609 INSTALLATION AND ELECTRICAL WIRING PROCEDURE A .0075" polyester gauge is provided to assist in setting the pickup gap. PN 605/UNILITE® MODULE: Apply a thin coat of silicone grease to the
|
Original
|
PDF
|
605/UNILITEÂ
PLACA DE ORIFICIO
|
Mallory Ignition
Abstract: No abstract text available
Text: TROUBLESHOOTING GUIDE FOR CAPACITIVE DISCHARGE CD IGNITION SYSTEMS Most CD boxes operate the same way, making for common basic test procedures. Most CD ignition boxes have two separate triggering circuits in them. One is for a regular points driver signal, which is a
|
Original
|
PDF
|
1483M
Mallory Ignition
|
Om175
Abstract: No abstract text available
Text: M a Wire Sets and Ignition Leads WIRE SETS FOR STERN DRIVES MagStar Marine spark plug wire sets are designed exclusively for marine engines and are the highest quality marine sets available anywhere in the world. Other wire set manufacturers generally use
|
Original
|
PDF
|
AUT-0076-1008
Om175
|
Untitled
Abstract: No abstract text available
Text: FORM 1577 06/03 INSTALLATION INSTRUCTIONS DISTRIBUTOR CAP IGNITION COIL REPLACEMENT COIL COVER COIL RUBBER INSULATOR GROUND STRAP NOT USED ON ALL MODELS CARBON BRUSH & SPRING CAP DISTRIBUTOR CAP COMPONENTS GENERAL INFORMATION 1. Disconnect the feed and module connectors from
|
Original
|
PDF
|
|
Mallory Ignition
Abstract: No abstract text available
Text: Hyfire 6EZ and 6EZ RPML Instruction Manual Part#: 6855M, 6856M FORM 1604 03/04 INSTALLATION INSTRUCTIONS HYFIRE 6EZ and 6EZ RPML SERIES ELECTRONIC IGNITION CONTROL PART NOS. 6855M 6EZ and 6856M (6EZ RPML) PLEASE READ THESE INSTRUCTIONS COMPLETELY BEFORE STARTING THE INSTALLATION
|
Original
|
PDF
|
6855M,
6856M
6855M
Mallory Ignition
|
Untitled
Abstract: No abstract text available
Text: FORM 641 REV. B 9/99 INSTALLATION INSTRUCTIONS COMP 9000 90 SERIES POINT TYPE DISTRIBUTOR OLD DISTRIBUTOR REMOVAL 1. Disconnect distributor point wire from negative () side of coil. STARTING THE ENGINE CAUTION: Before starting the engine, be sure all tools, wires
|
Original
|
PDF
|
|
Untitled
Abstract: No abstract text available
Text: FORM INST85551M 12/09 INSTALLATION INSTRUCTIONS PROMASTER SERIES PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING. You should always disconnect the battery, negative lead first, before working on the ignition system. When you are done reconnect the battery installing the negative lead first.
|
Original
|
PDF
|
INST85551M
8360M
|
|
Untitled
Abstract: No abstract text available
Text: FORM 1008 REV. A 01/02 INSTALLATION INSTRUCTIONS WINDOW RPM ACTIVATED SWITCH PART NO. 646 Parts Included in this kit: 1 RPM Activated Switch Part No. 646 1 U shaped crimp-on wire terminal 1 #6 x 1/4" sheet metal screw 2 Velcro strips WIRING PROCEDURE
|
Original
|
PDF
|
/SN5070
|
Untitled
Abstract: No abstract text available
Text: OPERATING INSTRUCTIONS 4-Stage RPM Activated Switch Part No. 636 CONNECTING THE 636 HOW TO SET THE RPM SWITCH The RED wire is connected to a switched 12 volt ignition source. Normally, this would be The 636 RPM switch has 3 buttons and an LED display. By pressing the MODE button,
|
Original
|
PDF
|
|
Mallory Ignition
Abstract: No abstract text available
Text: FORM 1104 REV. C 01/03 INSTALLATION INSTRUCTIONS BILLET COMPETITION DISTRIBUTOR SERIES NOS. 81 AND 84 COMP® S/S DISTRIBUTOR 32 SERIES NOTICE: THE COMP® S/S MAGNETIC BREAKERLESS DISTRIBUTOR SERIES AND BILLET COMPETITION DISTRIBUTOR SERIES NOS. 81 AND 84 ARE LEGAL IN CALIFORNIA ONLY FOR RACING
|
Original
|
PDF
|
1418M
Mallory Ignition
|
Untitled
Abstract: No abstract text available
Text: FORM 1185 05/05 INSTALLATION INSTRUCTIONS MAGNETIC BREAKERLESS DISTRIBUTOR This product is applicable to pre-1966 California and pre-1968 federally certified passenger cars. It is also applicable to non-emission controlled trucks and similar vehicles. It is not applicable or intended for use on any emission controlled vehicles
|
Original
|
PDF
|
pre-1966
pre-1968
2094M
|
Untitled
Abstract: No abstract text available
Text: INSTALLATION INSTRUCTIONS FORM INST11106M Rev B 08/14 COMP PUMP SERIES 110FI IN-LINE ELECTRIC FUEL PUMP PART NO. 11106M Parts included in this kit: 1 - Comp Pump 100FI Series electric in-line fuel pump 2 - Mounting brackets PERFORMANCE SPECIFICATIONS Please read these instructions completely before
|
Original
|
PDF
|
INST11106M
110FI
11106M
100FI
30amp
|
Mallory Ignition
Abstract: No abstract text available
Text: FORM 1214M REV. K 05/13 INSTALLATION INSTRUCTIONS UNILITE DISTRIBUTOR This product is applicable to pre-1966 California and pre-1968 federally certified passenger cars. It is also applicable to non-emission controlled trucks and similar vehicles. It is not applicable or intended for use
|
Original
|
PDF
|
1214M
pre-1966
pre-1968
Mallory Ignition
|
M60U1R5M250
Abstract: No abstract text available
Text: I M60 Series Multilayer Ceramic Capacitors MallorY GENERAL SPECIFICATIONS Ultra High Insulation Resistance and Withstand Voltage Voltage Range: 25,50, 100, 250WVDC Capacitance Range: .1 /j,F to 100 juF Excellent Noise Suppression Applications: Ignition Noise Suppression
|
OCR Scan
|
PDF
|
250WVDC
M60U2R2M100
M60U3R3M100
M60U4R7M100
M60U6R8M100
M60U10M100
M60U15M100
M60U22M100
M60U33M100
M60UR10M250
M60U1R5M250
|
173472M250Y
Abstract: MALLORY 150 CAPACITORS CEI 40-7 class Y MALLORY CAPACITORS 55897
Text: 173Y Series — Line-To-Ground Suppressor • MallorY Film-Foil Polypropylene / Radial Leads ■ ■ ■ ■ ■ ■ GENERAL SPECIFICATIONS Radial Leads Used in Line-to-Ground or Across-the-Line Applications Non-lnductively Wound Flame Retardant Case Meets UL94V0
|
OCR Scan
|
PDF
|
UL94V0
UL94V1
50/60HZ
1000VAC
1000h
1284/Indianapolis
46206-1284/Phone:
273-0090/Fax:
173472M250Y
MALLORY 150 CAPACITORS
CEI 40-7
class Y
MALLORY CAPACITORS
55897
|
M60U1M25
Abstract: M60U2R2M250
Text: I M60 Series Multilayer Ceramic Capacitors MallorY GENERAL SPECIFICATIONS Dissipation Factor: 2 .5 % M axim um Ultra High Insulation R esistance and W ithstand Voltage Voltage R ange: 2 5 ,5 0 , 100, 2 5 0 W V D C Insulation R esistance: 2=1000 i l x ¡j F or 1 0 ,0 0 0 M il.
|
OCR Scan
|
PDF
|
Coefficient197
M60U2R2M100
M60U3R3M100
M60U4R7M100
M60U6R8M100
M60U10M100
M60U15M100
M60U22M100
M60U33M100
M60UR10M250
M60U1M25
M60U2R2M250
|
Untitled
Abstract: No abstract text available
Text: I Multilayer Ceramic Capacitors M60 Series MallorY • ■ ■ ■ ■ i i i i i i i i i i i i i a t i i a i i i i i i i i i i i i a a a i a i i i i i i i i i i i i i i i a i i i i i i i i K Radial Leaded Conformally Coated GENERAL SPECIFICATIONS Ultra High Insulation
|
OCR Scan
|
PDF
|
Coefficie250
M60U2R2M250
M60U3R3M250
M60U4R7M250
M60U6R8M250
Company/7545
46214-3073/Phone:
273-0090/Fax:
273-2400/www
|