E213214
Abstract: FUSES GFN1 GFN20
Text: General Purpose US US Fuses General Purpose Fuses Midget Fuses 10x38 US Time Delay GFN GFN midget indicating fuses are available in 34 ratings from 1/10A through 30A. These timedelay fuses have built-in blown fuse indicators which pop out at the end of the fuse to visually
|
Original
|
PDF
|
10x38
1/10A
details10
GPUS67
GFN1/10
GFN15/100
GFN2/10
GFN3/10
GFN4/10
GFN6/10
E213214
FUSES
GFN1
GFN20
|
F206039
Abstract: Y206032 k2061 IEC 269-3
Text: Miniature Fuses IEC Fuses 5x20 High breaking capacity FC Fast Acting 250VAC from 0.16 to 10A Complying with IEC-127-2 Standard Sheet 5 Dimensions Product weight: 1.2g max. Packaging: in box of 1000 pieces. These fuses are available with axial leads : refer to data sheet
|
Original
|
PDF
|
250VAC
IEC-127-2
MI5FC25V0
F206039
Y206032
k2061
IEC 269-3
|
TRM-16
Abstract: TRM6 G218299 TRM30 TRM2 TRM Fuses V218817
Text: General Purpose US US Fuses General Purpose Fuses Midget Fuses 10x38 US Time Delay TRM Tri-onic TRM time-delay midget fuses are rated 250 volts AC and are offered in 36 ampere ratings from 1/10A to 30A. They have 12 seconds time delay at 200% rating to provide supplemental
|
Original
|
PDF
|
10x38
1/10A
250VAC
Delay17782
X222545
G201394
M214210
T215228
Q214719
Y215738
TRM-16
TRM6
G218299
TRM30
TRM2
TRM Fuses
V218817
|
Untitled
Abstract: No abstract text available
Text: IEC inlet filters FN 9260 General purpose power entry module with fuses • ■ ■ ■ Up to 10A current ratings IEC60950-compliant For one or two fuses Optional medical versions B type Technical specifications Maximum continuous operating voltage: Operating frequency:
|
Original
|
PDF
|
IEC60950-compliant
250VAC,
50/60Hz
400Hz
2000VAC
2500VAC
760VAC
1700VDC
EN60601-1
EN60601-1
|
Untitled
Abstract: No abstract text available
Text: IEC inlet filters FN 9260 General purpose power entry module with fuses • ■ ■ ■ Rated currents up to 10A For one or two fuses Optional medical versions B type Snap-in versions (S type) Technical specifications Maximum continuous operating voltage:
|
Original
|
PDF
|
250VAC,
50/60Hz
400Hz
2000VAC
2500VAC
760VAC
1700VDC
9260S
|
Untitled
Abstract: No abstract text available
Text: IEC inlet filters FN 9260 General purpose power entry module with fuses • ■ ■ ■ Rated currents up to 10A For one or two fuses Optional medical versions B type Snap-in versions (S type) Technical specifications Maximum continuous operating voltage:
|
Original
|
PDF
|
250VAC,
50/60Hz
400Hz
2000VAC
2500VAC
760VAC
1700VDC
9260S
2768-m
|
Untitled
Abstract: No abstract text available
Text: IEC inlet filters FN 9260 General purpose power entry module with fuses n Rated currents up to 10A For one or two fuses n Optional medical versions B type n Snap-in versions (S type) Approvals n Technical specifications Maximum continuous operating voltage:
|
Original
|
PDF
|
C/230V
Mil-HB-217F)
250VAC,
50/60Hz
400Hz
2000VAC
2500VAC
760VAC
1700VDC
9260S
|
Untitled
Abstract: No abstract text available
Text: IEC Inlet Filters FN 390 Versatile Filtered Power Entry Module Rated currents up to 10A For one or two fuses Approvals Fuses Ø6.3 x 32mm or Ø5 x 20mm 2-pole rocker switch Voltage selector Optional earth line choke E type Technical specifications Maximum continuous operating voltage: 250VAC, 50/60Hz
|
Original
|
PDF
|
250VAC,
50/60Hz
400Hz
2000VAC
760VAC
C/76185
|
gfn20
Abstract: GFN4
Text: GFN 1-1/2” x 13/32” MIDGET FUSES GFN midget indicating fuses are available in ratings from 1/10A through 30A. These time-delay fuses have built-in blown fuse indicators which pop out at the end of the fuse to visually indicate when the fuse has operated to open the circuit. Indicators may
|
Original
|
PDF
|
1/10A
2-30A
GFN1/10
GFN15/100
GFN2/10
GFN3/10
GFN4/10
GFN6/10
GFN8/10
GFN1-4/10
gfn20
GFN4
|
Untitled
Abstract: No abstract text available
Text: IEC Inlet Filters FN 390 Versatile Filtered Power Entry Module Rated currents up to 10A For one or two fuses Approvals Fuses Ø6.3 x 32mm or Ø5 x 20mm 2-pole rocker switch Voltage selector Optional earth line choke E type Technical specifications Maximum continuous operating voltage: 250VAC, 50/60Hz
|
Original
|
PDF
|
250VAC,
50/60Hz
400Hz
2000VAC
760VAC
C/76185
|
Untitled
Abstract: No abstract text available
Text: IEC Inlet Filters FN 9260 General Purpose Power Entry Module with Fuses Rated currents up to 10A For one or two fuses Approvals Optional safety version A type Complies with IEC/EN 60601-1 Snap-in versions (S type) Technical specifications Design corresponding to:
|
Original
|
PDF
|
2000VAC
2500VAC
760VAC
1700VDC
250VAC,
50/60Hz
C/230V
Mil-HB-217F)
d76185
|
Untitled
Abstract: No abstract text available
Text: IEC Inlet Filters FN 9260 General Purpose Power Entry Module with Fuses Rated currents up to 10A For one or two fuses Approvals Optional safety version A type Complies with IEC/EN 60601-1 Snap-in versions (S type) Technical specifications Design corresponding to:
|
Original
|
PDF
|
2000VAC
2500VAC
760VAC
1700VDC
250VAC,
50/60Hz
C/230V
Mil-HB-217F)
d76185
|
Untitled
Abstract: No abstract text available
Text: General Purpose Power Entry Module with Fuses IEC Inlet Filters / Power Entry Modules FN 9260 Rated currents up to 10A For one or two fuses Approvals Optional safety version A type Optional medical versions (B type) according to IEC/EN 60601-1 Snap-in versions (S type)
|
Original
|
PDF
|
C/230V
Mil-HB-217F)
|
Schaffner 1393
Abstract: f 9222 l Schaffner catalog 139X EN 133200 iec 60939 SCHAFFNER FN fusibles
Text: Versatile power entry module FN 390 • • • • up to 10A current ratings IEC 950-compliant twin fuse configurations only general-purpose or high-performance filtering for one or two fuses (Ø5 x 20 or Ø6.3 x 32mm) • • • • Nennstrom bis 10A
|
Original
|
PDF
|
950-compliant
110/230V
250VAC
389B-6/21
394E-2
Schaffner 1393
f 9222 l
Schaffner catalog
139X
EN 133200 iec 60939
SCHAFFNER FN
fusibles
|
|
33P29
Abstract: 9260SB-10-06-20
Text: IEC inlet filters FN 9260 General purpose power entry module with fuses n Rated currents up to 10A For one or two fuses n Optional medical versions B type according to IEC/EN 60601-1 n Snap-in versions (S type) Approvals n Technical specifications Maximum continuous operating voltage:
|
Original
|
PDF
|
C/230V
Mil-HB-217F)
250VAC,
50/60Hz
400Hz
2000VAC
2500VAC
760VAC
9260S
2768-m
33P29
9260SB-10-06-20
|
EMC 560
Abstract: UL 94v-2 Schaffner 1393-6-05-11
Text: IEC inlet filters FN 390 Versatile filtered power entry module • ■ ■ ■ ■ ■ Rated currents up to 10A For one or two fuses Fuses Ø6.3 x 32mm or Ø5 x 20mm 2-pole rocker switch Voltage selector Optional earth line choke E type Technical specifications
|
Original
|
PDF
|
C/230V
Mil-HB-217F)
250VAC,
50/60Hz
400Hz
2000VAC
760VAC
EMC 560
UL 94v-2
Schaffner 1393-6-05-11
|
Untitled
Abstract: No abstract text available
Text: ELECTRONIC / GLASS FUSES GSD / GSD-V GSF / GSF-V Ceramic Body Fasting Acting 5mm x 20 mm 1-1/2” Axial Leads Optional Ceramic Body Time Delay 5mm x 20 mm 1-1/2” Axial Leads Optional 1/20A through 10A, 250VAC - UL & CSA Recognized 1/20A through 6-3/10A, 250VAC - KEMA Approved
|
Original
|
PDF
|
1/20A
250VAC
6-3/10A,
6-13/10A,
|
UL 1045, TV3
Abstract: f 9222 l "Rocker Switch" 10A 230V UL 389B-6 pc 9260 385B FN370 UL 1045
Text: General-purpose power entry module FN 9260 • • • • up to 10A current ratings IEC 950-compliant for one or two fuses Ø5 x 20mm optional medical version (B type) • • • • Nennstrom bis 10A IEC 950 konform Für eine oder zwei Sicherungen (Ø5 x 20mm)
|
Original
|
PDF
|
950-compliant
110/230V
250VAC
389B-6/21
394E-2
UL 1045, TV3
f 9222 l
"Rocker Switch" 10A 230V UL
389B-6
pc 9260
385B
FN370
UL 1045
|
SCHAFFNER FN 9260
Abstract: No abstract text available
Text: IEC Inlet Filters FN 9260 General Purpose Power Entry Module with Fuses n n n n n Rated currents up to 10A For one or two fuses Optional safety version A type Optional medical versions (B type) according to IEC/EN 60601-1 Snap-in versions (S type) Technical specifications
|
Original
|
PDF
|
C/230V
Mil-HB-217F)
250VAC,
50/60Hz
400Hz
2000VAC
2500VAC
760VAC
SCHAFFNER FN 9260
|
Untitled
Abstract: No abstract text available
Text: IEC inlet filters FN 9260 General purpose power entry module with fuses n n n n n Rated currents up to 10A For one or two fuses Optional safety version A type Optional medical versions (B type) according to IEC/EN 60601-1 Snap-in versions (S type) Technical specifications
|
Original
|
PDF
|
C/230V
Mil-HB-217F)
250VAC,
50/60Hz
400Hz
2000VAC
2500VAC
760VAC
|
Untitled
Abstract: No abstract text available
Text: IEC Inlet Filters FN 9260 General Purpose Power Entry Module with Fuses n n n n n Rated currents up to 10A For one or two fuses Optional safety version A type Optional medical versions (B type) according to IEC/EN 60601-1 Snap-in versions (S type) Technical specifications
|
Original
|
PDF
|
C/230V
Mil-HB-217F)
250VAC,
50/60Hz
400Hz
2000VAC
2500VAC
760VAC
|
Untitled
Abstract: No abstract text available
Text: EMC/EMI Products IEC Inlet Filters FN 9260 General Purpose Power Entry Module with Fuses n n n n n Rated currents up to 10A For one or two fuses Optional safety version A type Optional medical versions (B type) according to IEC/EN 60601-1 Snap-in versions (S type)
|
Original
|
PDF
|
250VAC,
50/60Hz
400Hz
2000VAC
2500VAC
760VAC
1700VDC
|
Schaffner 1393-6-05-11
Abstract: fn 1393-10-05-11 FN 394-1/05-11 560-2 394e-1-05-11 FN 1394-2.5-05-11 FN 394-2.5/05-11 FN 394-6/05-11 "Rocker Switch" 10A 230V UL Schaffner 1393
Text: IEC inlet filters FN 390 Versatile filtered power entry module n n n n n n Rated currents up to 10A For one or two fuses Fuses Ø6.3 x 32mm or Ø5 x 20mm 2-pole rocker switch Voltage selector Optional earth line choke E type Technical specifications Maximum continuous operating voltage:
|
Original
|
PDF
|
C/230V
Mil-HB-217F)
2768-m
22768-m
Schaffner 1393-6-05-11
fn 1393-10-05-11
FN 394-1/05-11
560-2
394e-1-05-11
FN 1394-2.5-05-11
FN 394-2.5/05-11
FN 394-6/05-11
"Rocker Switch" 10A 230V UL
Schaffner 1393
|
gfn20
Abstract: fuse 10KA GFN3 GFN30 GFN4 blown fuse indicator APPLICATIONS
Text: GFN 1-1/2” X 13/32” GFN midget indicating fuses are available in 34 ratings from 1/10A through 30A. These time-delay fuses have built-in blown fuse indicators which pop out at the end of the fuse to visually indicate when the fuse has operated to open the
|
Original
|
PDF
|
1/10A
GFN1/10
GFN15/10
GFN2/10
GFN3/10
GFN4/10
GFN6/10
GFN8/10
GFN1-4/10
GFN1-6/10
gfn20
fuse 10KA
GFN3
GFN30
GFN4
blown fuse indicator APPLICATIONS
|